Back
Hot

ike2

2-WIRE THERMOPLASTIC RUBBER PROBE

Airtight 2 wire double insulation rubber probe

-Pt100, Pt1000, thermistor (NTC) sensing element
-IP-68 tightness degree
-Suitable for long-time immersion in corrosive liquids
-Available with a stainless steel case

LinkedinEmail

Technical data

Product type
probe
Type of sensor
thermoresistance
Sensor construction type
direct cable
Sensor protection
plastic sheath
plastic body inserted into metallic protection
Sensing element
Pt100 ? @ 0°C
Pt1000 ? @ 0°C
NTC R(25°C)=10Kohm ±1%, beta(25/85)=3977
NTC R(25°C)=10Kohm ±1%, beta(25/85)=3435
NTC R(25°C)=10Kohm ±3%, beta(25/85)=3977
NTC R(25°C)=2.7Kohm ±1%, beta(25/85)=3977
NTC R(25°C)=10Kohm, Beta (25/85) =3969, tol ±0.2°C (0-70°C)
Sensing Element configuration
single 2-wire
Output signal type
thermoresistance
thermistor
Accuracy class in accordance to IEC751 (*)
(*) Pt 100 cl.A only available with 3 or 4 wires, cl.AA 4 wires only; Pt 1000 cl. A available with 2 wires only for cable lengths below 1 m, for longer cables only available with 3 or 4 wires, cl. AA 3 wires for cable lengths below 1 m, for longer cables only 4 wires.
cl. A
cl. B
Sensing element operating temperature range
-40 ÷105°C
Insulation resistance
100 M ?@ 1000 Vdc.
Dielectric strength
3750 Vac
Sensing part connection
cable
Transition sleeve
no
Plastic bulb dimension
Ø 5 x20 mm
Plastic bulb material
TPE (MOULDED)
Extension cable
TPE 2 conductors
EXTENSION CABLE
Cable conductors
copper tinned
Number of cable conductors
2
Conductor dimension
AWG 24
Conductor feature
strand (7 wire)
Primary insulation
PP (polypropylene)
Outside diameter of single conductor (*)
(*) primary insulation
about Ø 1.05 mm
Primary insulation colour
1 white, 1 black
Secondary insulation colour
black
Cable size or external shape
about Ø 3,3 mm
Working temperature
-40 ÷105°C (6h @150°C)
Note
twisted conductors
Cable lenghts E= (subject to feasibility check)
500 mm ÷100 m
Fixing system
bare stem
Protective sheath
(*) test in water in accordance with IEC 751. Time taken to reach 63.2% of temperature step
without protection
Response time < 10 seconds(*)
Ø 6 x L=30 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=40 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=50 mm
Response time < 15 seconds(*)
Sheet material INOX
Ø 6 x L=60 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=70 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=100 mm
Response time < 15 seconds(*)
Sheet material INOX
Ø 6 x L=150 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=200 mm
Sheet material INOX
Response time < 15 seconds(*)
Terminal electrical connection
stripped wires
Product marking
marked with production date and traceability code (FOR CONSTRUCTION WITH STAINLESS STEEL TUBE ONLY)
International protection marking (*)
(*) According to IEC 60529
IP68

Drawing

2-WIRE THERMOPLASTIC RUBBER PROBE

Download

No download