Back
Hot

tctx

THERMOCOUPLE FOR MOULDS WITH REFRACTORY POLYMER TRANSITION

– mineral insulated construction (M.I.C.)
– Kapton cable with easy stripping and evident colors
– refractory polymer transition (Tmax 500°C)

LinkedinEmail

Technical data

Product type
probe
Type of sensor
thermocouple
Sensor construction type
with mineral compact insulation (M.I.C.)
Sensor protection
metal sheath
Removable insert
no
Thermocouple calibration
type K (cromel-alumel)
Sheet material INCONEL 600
Sensing part maximum working temperature 1100°C
type J (iron-constantan)
Sheet material AISI 304
Sensing part maximum working temperature 600°C
Number of elements (T/C) (*)
(*) Number Elements (T/C) asterisco
single
Hot measuring joint
insulated
grounded
Output signal type
thermocouple
Accuracy class in accordance with IEC 584
2 (STANDARD)
1 (SPECIAL)
Sheath diameter d=
Ø 1 mm
Ø 1.5 mm
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M ?@ 100 Vdc.
Stem length L=
100 mm
200 mm
300 mm
400 mm
500 mm
Realizable sheat lenghts L= (subject to feasibility check)
50 mm ÷900 mm
Sensing part connection
cable
Transition sleeve
yes
Transition sleeve type
REFRACTORY POLYMER Ø 5 x 16 mm
Transition sleeve diameter
Ø 5 mm
Transition sleeve length
16 mm
Transition sleeve material
REFRACTORY POLYMER (OVERMOULDED)
Maximum transition temperature
500°C
Fixing system
bare stem
Cable extension E=
1 m
2 m
4 m
Cable lenghts E= (subject to feasibility check)
300 mm ÷4 m
Terminal electrical connection
stripped wires
Breaking strain
P max 15 Kgf
Compensated cable
PTFE + Kapton + Kapton; type J IEC
Temperatura massima cavo 300°C
PTFE + Kapton + Kapton; type J DIN
Temperatura massima cavo 300°C
PTFE + Kapton + Kapton; type K IEC
Temperatura massima cavo 300°C
PTFE + Kapton + Kapton; type J ANSI
Temperatura massima cavo 300°C
PTFE + Kapton + Kapton; type K ANSI
Temperatura massima cavo 300°C
EXTENSION CABLE
Cable conductors
tipo J
Norm of reference
ANSI MC96.1
Number of cable conductors
2
Conductor dimension
AWG 24
Conductor feature
strand (7 wire)
Primary insulation
PTFE + POLYIMIDE
Secondary insulation
POLYIMIDE
Cable size or external shape
flat wire 2.15 x 1.30 mm approx.
Working temperature
-200 ÷200°C (2h @350°C)
EXTENSION CABLE
Cable conductors
tipo J
Norm of reference
IEC 584
EXTENSION CABLE
Cable conductors
tipo J
Norm of reference
DIN 43710
EXTENSION CABLE
Cable conductors
tipo K
Norm of reference
ANSI MC96.1
EXTENSION CABLE
Cable conductors
tipo K
Norm of reference
IEC 584

Drawing

THERMOCOUPLE FOR MOULDS WITH REFRACTORY POLYMER TRANSITION

Download

No download

TCT thermocouple for hot runners

TCT thermocouple system for temperature measurements in hot runners and manifolds. The new patented transition construction allow an high resistance to high temperatures and high pull strenght